{"id":7460,"date":"2026-11-19T15:17:52","date_gmt":"2026-11-19T21:17:52","guid":{"rendered":"https:\/\/us.rs-online.com\/expert\/?p=7460"},"modified":"2026-11-19T15:19:16","modified_gmt":"2026-11-19T21:19:16","slug":"problem-solved-machine-safety-for-facilities-and-logistics","status":"publish","type":"post","link":"https:\/\/us.rs-online.com\/expert\/problem-solved-machine-safety-for-facilities-and-logistics\/","title":{"rendered":"Problem? Solved! \u2013 Machine safety for facilities and logistics"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">In this edition of the new Problem? Solved! RS Expert Advice series,Renato Osaki, the Safety Components Product Manager at Omron Automation, explains how smart, turnkey safety relays, light curtains, and guard locking switches solve common machine safety challenges in sprawling conveyor systems and automated cells.<\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"margin-top:50px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120787\/Expert%20Advice\/Figure_1_Renato_Osaki_amqco2.jpg\" alt=\"\"\/><figcaption class=\"wp-element-caption\">Renato Osaki, the Safety Components Product Manager at Omron Automation<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<p class=\"wp-block-paragraph\">RS serves industrial customers who build and maintain assets and infrastructure throughout the discrete and process manufacturing, facilities and intralogistics, and energy and utilities industries \u2014 providing an extensive array of proven product solutions from trusted suppliers as well as a selection of value-added solutions and services designed to solve customers\u2019 pain points. The new <a href=\"https:\/\/us.rs-online.com\/expert\/category\/problem-solved\/\">\u201cProblem? Solved!\u201d<\/a> RS Expert Advice series features <a href=\"https:\/\/us.rs-online.com\/expert\/category\/experts-behind-the-advice\/\">RS experts<\/a> and supplier experts addressing common industrial challenges they can help you overcome.&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For this edition, we spoke toRenato Osaki, the Safety Components Product Manager at Omron Automation to learn how smart, turnkey safety relays, light curtains, and guard locking switches solve common machine safety challenges \u2014 including installation and system complexity, labor constraints, diagnostic blind spots, and unplanned downtime \u2014 in sprawling conveyor systems and automated cells.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Hi Renato. You joined us today to discuss how facilities and logistics operators \u2014 including discrete manufacturers, warehousers, and distributors \u2014 struggle to implement comprehensive machine safety across conveyor systems and automation cells without increasing system complexity, downtime, or wiring effort, as well as how safety relays, light curtains, and guard locking switches can help. So, let\u2019s dive in problem first.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Balancing robust safety compliance with operational efficiency is one of the toughest acts in modern logistics and manufacturing. Conveyor systems and automation cells aren&#8217;t compact, standalone machines; they span massive physical distances. So, field safety devices, like safety relays, emergency stops, rope pulls, light curtains, and guard locking switches, must be distributed over tens or hundreds of meters.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These sprawling layouts and distributed devices create several distinct challenges for traditional machine safety systems, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Hardwiring challenges.<\/strong> Distributing safety devices over long distances introduces physical footprint and layout constraints. Since Category 3 and 4 safety standards require dual-channel redundancy, every field safety device in these architectures has a dedicated redundant cable pair running back to a hardwired safety relay in a central control cabinet. This requires twice as much cable stretching over long distances, as well as massive amounts of conduit, labor, documentation, and cabinet space, which is often in short supply. And with hundreds of point-to-point terminations in these architectures, the likelihood of wiring mistakes during installation or modification increases exponentially.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Diagnostic blind spots and downtime.<\/strong> When an emergency stop (e-stop) or safety switch trips in a conventional series-wired safety circuit, the central controller only knows that the overall safety circuit opened \u2014 not which specific device caused it. So, maintenance technicians have to manually walk the line to identify the tripped device, which can turn a minor error into an expensive block of unscheduled downtime.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>System complexity.<\/strong> To avoid massive wiring bundles, expansive facilities often adopt networked safety protocols like CIP Safety or EtherCAT. The problem is, while this effectively reduces physical cabling, it drastically increases system complexity by introducing safety PLCs that require specialized programming knowledge to write, validate, and troubleshoot safety code, and the industry is facing persistent skilled labor shortages. So, choosing a solution that demands highly experienced engineers creates a real vulnerability.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Inflexibility.<\/strong> Traditional hardwired safety loops require technicians to disconnect and rewire extensive cable runs every time a line shifts, which halts production and introduces opportunities for error. But modern warehousing thrives on agility, integrating modular conveyor segments and mobile robots to make it quick and easy to reconfigure layouts and optimize throughput.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">How do safety relays help?<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:85%\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+RELAYS\">Smart, modular safety relays<\/a> effectively bridge the gap between traditional safety relays, which can contribute to hardwiring headaches in sprawling conveyor systems and automated cells, and costly, complex safety PLCs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That isn\u2019t to say, of course, that traditional safety relays and advanced safety controllers don\u2019t have their roles. Standard safety relays remain the most cost-effective choice for simple, compact setups \u2014typically with up to three safety devices. And advanced safety controllers with network communication and remote I\/O capabilities are ideally suited for expansive production lines featuring dozens or hundreds of devices distributed over long distances.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Smart, configurable safety relays fill the space in between, providing the ideal solution for mid-sized applications managing five to 20 devices through a single controller. Key advantages for these applications include:<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:15%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120792\/Expert%20Advice\/Figure_2_G9SX-SM032_Safety_Relay_nsimm8.jpg\" alt=\"\"\/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<ul style=\"margin-top:-14px\" class=\"wp-block-list\">\n<li><strong>Daisy-chain architectures.<\/strong> Traditional safety relays require a dedicated pair of wires for each field device, meaning that 10 safety door switches, for instance, require 20 individual conductors running all the way back to the panel. Modern modular safety relays reduce the amount of cabling required by allowing technicians to daisy-chain multiple field devices in a single loop while maintaining Category 4 \/ PL e safety ratings and individual diagnostics.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Advanced safety functions without the complexity of a safety PLC.<\/strong> Traditional safety relays are generally designed to perform a straightforward task: monitor a safety device and safely remove power when that device is triggered. More advanced modular safety relays can go several steps further, incorporating functions such as safety-rated logic between zones, configurable time-delayed outputs, feedback monitoring, and coordinated control of multiple machine sections. These capabilities allow designers to create more sophisticated safety strategies \u2014 for example, stopping one conveyor zone while allowing another to continue operating, or maintaining an output for a controlled period while equipment comes to a safe stop \u2014 without having to employ a programmable safety controller. For mid-sized logistics applications, this can provide much of the functional flexibility associated with a safety PLC while retaining the relative simplicity of a relay-based architecture.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For logistics operations, this added flexibility can simplify the path to a more capable safety architecture. Rather than choosing between a basic relay solution that may be too limited and a programmable safety system that may be more complex than the application requires, designers can implement scalable safety functions that better match the size and needs of the equipment. The result is a practical approach that supports safer machine operation, easier system expansion, and greater design flexibility as automation requirements evolve.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How do safety light curtains help?<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:80%\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+Light+curtains\">Safety light curtains<\/a> provide non-contact perimeter and area protection, instantly stopping hazardous machinery when a person or object breaks the sensing field. Modern light curtains also simplify installation, operation, and troubleshooting in long conveyor segments and automated cells by incorporating smart diagnostics, advanced optical capabilities, and reduced wiring architectures. Key capabilities of modern safety light curtains include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Optical synchronization.<\/strong> Advanced light curtains sync emitters and receivers optically rather than requiring physical sync wiring between heads. This design reduces excessive wiring and eliminates potential failure points across long conveyor spans.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120797\/Expert%20Advice\/Figure_3_F3SG-SR_Light_Curtain_Installed_wb9uvw.jpg\" alt=\"\"\/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<ul style=\"margin-top:-14px\" class=\"wp-block-list\">\n<li><strong>Multi-segment cascading.<\/strong> Technicians can connect multiple light curtain segments in series using a single cable run back to the control panel. This architecture reduces manual wiring effort and simplifies safeguarding for complex, L-shaped, and multi-sided machine perimeters.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Built-in muting and blanking.<\/strong> Integrated muting and blanking functions allow pallets, totes, and manufactured parts to pass freely through the light curtain field while maintaining full protection for human operators. This capability prevents false trips on active conveyor lines without requiring separate, complex external muting controllers.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Visual beam alignment.<\/strong> On-body area beam indicators (ABIs) and integrated LED status strips convey real-time optical alignment quality along the length of light curtains during physical setup. This immediate visual feedback allows technicians to rapidly and accurately align emitter and receiver heads without bringing specialized alignment tools onto the floor.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Intelligent optical diagnostics.<\/strong> Intelligent diagnostic taps, such as Bluetooth or IO-Link interface modules, transmit granular optical data directly to HMIs, non-safety PLCs, or mobile devices. This provides maintenance teams with real-time warnings about low signal intensity, dirty lenses, and specific blocked beam locations and enables them to troubleshoot minor errors before a nuisance trip halts production.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ruggedized physical construction.<\/strong> Heavy-duty IP67 and IP69K housings paired with vibration-resistant mounting brackets protect internal optical components against harsh washdowns, oil, dust, and structural flexing. Built-in ambient light immunity prevents false trips caused by overhead LED lighting or reflective packaging materials moving along an active conveyor line.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">How do guard locking switches help?<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:80%\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+Safety+Interlock+Switches+and+Guard+Locking+Devices&amp;page=1\">Guard locking safety switches<\/a> protect personnel from high-inertia machinery and hazardous automated cells by physically locking access doors or gates shut until hazardous motion ceases completely. Modern guard locking switches combine high physical holding forces with smart RFID technology and simplified wiring to prevent tampering, streamline installation, and ensure strict safety compliance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Key capabilities of modern guard locking switches include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>High retention holding force.<\/strong> Heavy-duty locking mechanisms provide physical holding forces exceeding 1,800 to 3,000 Newtons, preventing operators from forcing open guards while hazardous flywheels, blades, or robotic arms coast down to a complete stop.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120802\/Expert%20Advice\/Figure_4_D4SL-N_Door_Lock_Installed_u0szxp.jpg\" alt=\"\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<ul style=\"margin-top:-14px\" class=\"wp-block-list\">\n<li><strong>RFID anti-tamper coding.<\/strong> RFID-coded actuators satisfy ISO 14119 high-level anti-tamper requirements by assigning unique digital signatures to individual interlock heads. This technology prevents operators from bypassing safety switches using spare keys, tape, or secondary actuators.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Power-to-unlock design.<\/strong> Internal mechanical springs keep access guards locked shut during power outages or emergency stops without requiring electrical power. An internal solenoid energizes to release the latch only after a safety controller confirms machine motion has stopped, preventing access to coasting equipment.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Emergency escape release mechanisms.<\/strong> Internal escape release handles allow personnel trapped inside a safeguarded enclosure to unlock and push open the door manually from the inside, ensuring immediate egress without requiring control power or tools.<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Series wiring and granular diagnostics.<\/strong> Integrated solid-state RFID interlocks allow technicians to daisy-chain multiple guard locking switches in series while maintaining higher safety ratings. Built-in status LEDs and diagnostic outputs send individual door status directly to PLCs and HMIs, allowing maintenance teams to identify open guards instantly.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Please introduce a few Omron Automation solutions that can help facilities and logistics operators overcome common challenges when implementing comprehensive machine safety across conveyor systems and automation cells.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Omron Automation pairs application expertise and engineering services with an extensive portfolio of field-proven machine safety products to streamline protection across sprawling conveyor lines and automated cells. This integrated approach enables facility operators, includingdiscrete manufacturers, warehousers, and distributors, to achieve full regulatory compliance while eliminating excess system complexity, field wiring effort, and expensive unscheduled downtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Omron safety application engineers provide early-stage gap analysis and safety design estimates to reveal any hazard points before equipment fabrication begins. Our experienced engineering teams identify necessary countermeasures, safety circuits, and interlocks upfront, enabling operators to build compliant machines from the start, without the added cost of post-installation modifications. Our application specialists evaluate existing facility layouts to suggest targeted retrofits that enhance worker safety without interrupting material flow.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Omron\u2019s physical hardware portfolio translates these engineering strategies into ruggedized, field-ready protection built for harsh operating conditions. Heavy-duty IP65, IP67, and IP69K enclosures protect field devices against airborne dust, mechanical vibration, and high-pressure washdowns across demanding logistics and manufacturing environments, and certified safety compliance across the entire Omron ecosystem guarantees long-term reliability and adherence to global safety standards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Three core Omron hardware solutions engineered to help operators overcome common conveyor and automated cell challenges include:<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120808\/Expert%20Advice\/Figure_5_G9SX-SM_Safety_Relays_i5ay4r.jpg\" alt=\"\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+G9SX-SM\"><strong>G9SX-SM standstill monitoring safety relays.<\/strong><\/a> These safety relays feature internal circuitry that measures motor back electromotive force (BEMF) through existing power lines inside the control cabinet. This cabinet-centric logic removes fragile physical speed sensors, proximity sensors, and shaft encoders from dirty, vibrating conveyor lines and eliminates the need for hundreds of feet of shielded cabling. Omron G9SX-SM safety relays also feature front-panel LED indicators that reveal real-time diagnostic status for rapid troubleshooting. This standalone architecture achieves Category 4 \/ Performance Level e (PL e) safety without a Safety PLC, software programming, or sensitivity tuning, and all they require for setup is standard panel wiring and a time-delay switch. Ideal applications include guard-locking safety doors on automated and robotic cells or high-inertia conveyors in manufacturing and logistics applications, because instead of forcing operators to wait for an arbitrarily long, hard-coded timer to unlock the door, G9SX-SM relays safely unlock the door at the exact millisecond the motor stops spinning \u2014 maximizing safety while keeping cycle times as fast as possible.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120812\/Expert%20Advice\/Figure_6_F3SG-SR_Safety_Light_Curtain_rkjfsu.jpg\" alt=\"\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+F3SG-SR&amp;page=1\"><strong>F3SG-SR series safety light curtains.<\/strong><\/a> These light curtains feature a multi-segment cascading architecture that daisy-chains sensor pairs in L- or U-shaped configurations using a single main cable run. This end-to-end design eliminates mechanical dead zones at corners to compress physical cell footprints, while an optional <a href=\"https:\/\/us.rs-online.com\/product\/omron-automation\/f39-sgit-il3\/71883965\/\">Intelligent Tap accessory<\/a> pushes configurations and diagnostic data over a single network link instead of running heavy multi-conductor cabling along long conveyors. On-body three-color area beam indicators (ABIs) reveal real-time optical alignment to catch drift from dust or vibration before nuisance trips occur, and the Intelligent Tap doubles as an automatic backup module that restores saved parameters and cuts unit replacement downtime by up to 90% without a PC, software, or safety engineer. And since F3SG-SR series light curtains feature integrated safety functions that offloads complex safety PLC coding, they allow pallets and parts to flow freely through perimeter guarding sensing fields and material feed access points, which makes them ideal for maintaining uninterrupted material throughput in automated cells.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1795120817\/Expert%20Advice\/Figure_7_D4SL-N_Safety-Door_Locks_kra4ww.jpg\" alt=\"\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:75%\">\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+D4SL-N\"><strong>D4SL-N safety guard locking switches.<\/strong><\/a> These multi-contact guard locking switches feature quick-connector wiring models and removable terminal blocks that accept pre-molded cordsets and cut field installation time by over 50%. A consolidated six-contact internal architecture handles safety channels, solenoid control, and independent door and lock monitoring through a single cable, shrinking cable track footprints while eliminating diagnostic logic blind spots. Four-direction rotatable heads and wide key-insertion tolerances absorb gate sagging and operator slamming in automated cells, while heavy-duty 1,300N holding forces keep maintenance hatches locked securely against constant conveyor vibration to prevent false trips. D4SL-N switches also feature a slide-key mechanism with an internal release lever that allows trapped operators to manually unlock and push open access doors from the inside. This makes them well-suited for securing physical access points around automated cells, reducing personnel risk, and avoiding unnecessary mechanical or electrical downtime.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Simplify machine safety across conveyor lines and automated cells with Omron Automation and RS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Omron Automation is a trusted global supplier of industrial automation products and solutions, ranging from sensors and safety devices to power, control, vision, and motion technologies and fully integrated automation solutions, including robotic systems. Omron Automation products and solutions are backed by more than 90 years of research, design, and manufacturing experience, built to leverage cutting-edge technologies, like AI and the IIoT, and engineered to enable a more sustainable future.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RS offers an extensive portfolio of <a href=\"https:\/\/us.rs-online.com\/manufacturers\/omron-automation\/\">Omron Automation products<\/a>, including a vast selection of <a href=\"https:\/\/us.rs-online.com\/lp\/omron-automation\/safety-solutions\/\">machine safety solutions<\/a>, and RS technical specialists collaborate directly with Omron safety application engineers to support customers through early-stage hazard gap analyses, safety design estimates, and risk compliance evaluations. Product selections extend from <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+RELAYS\">safety relays<\/a>, like the <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+G9SX-SM\">G9SX-SM series<\/a>, <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+Light+curtains\">safety light curtains<\/a>, like the <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+F3SG-SR&amp;page=1\">F3SG-SR series<\/a>, and <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+Safety+Interlock+Switches+and+Guard+Locking+Devices&amp;page=1\">guard locking switches<\/a>, like the <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=OMRON+D4SL-N\">D4SL series<\/a>, to <a href=\"https:\/\/us.rs-online.com\/lp\/omron-automation\/panel-building-solutions\/\">industrial control panel products<\/a>, <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=omron+power+supplies&amp;page=1&amp;refinements=%7B%22brands%22%3A%5B%7B%22value%22%3A%22Omron+Automation%22%2C%22label%22%3A%22Omron+Automation%22%7D%5D%7D\">power products<\/a>, <a href=\"https:\/\/us.rs-online.com\/sensors\/?refinements=%7B%22brands%22%3A%5B%7B%22value%22%3A%22Omron+Automation%22%2C%22label%22%3A%22Omron+Automation%22%7D%5D%7D\">sensors<\/a>, <a href=\"https:\/\/us.rs-online.com\/switches\/?refinements=%7B%22brands%22%3A%5B%7B%22value%22%3A%22Omron+Automation%22%2C%22label%22%3A%22Omron+Automation%22%7D%5D%7D\">switches<\/a>, <a href=\"https:\/\/us.rs-online.com\/plcs-hmis\/?refinements=%7B%22brands%22%3A%5B%7B%22value%22%3A%22Omron+Automation%22%2C%22label%22%3A%22Omron+Automation%22%7D%5D%7D\">PLCs and HMIs<\/a>, <a href=\"https:\/\/us.rs-online.com\/motors-motor-controls\/?page=1&amp;refinements=%7B%22brands%22%3A%5B%7B%22value%22%3A%22Omron+Automation%22%2C%22label%22%3A%22Omron+Automation%22%7D%5D%7D\">motors and motor controls<\/a>, and <a href=\"https:\/\/us.rs-online.com\/catalogsearch\/result\/?q=omron+automation+&amp;refinements=%7B%22brands%22%3A%5B%7B%22value%22%3A%22Omron+Automation%22%2C%22label%22%3A%22Omron+Automation%22%7D%5D%7D&amp;searchResults=cobot\">robotic systems<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For more information about <a href=\"https:\/\/automation.omron.com\/en\/us\/products\/families\/safety-logic-devices-relays\">Omron Automation safety relays<\/a>, <a href=\"https:\/\/automation.omron.com\/en\/us\/products\/families\/safety-light-curtains\">light curtains<\/a>, and <a href=\"https:\/\/automation.omron.com\/en\/us\/products\/families\/safety-interlock-door-switches\">safety interlock door switches<\/a>, including the <a href=\"https:\/\/automation.omron.com\/en\/us\/products\/family\/G9SX\">G9SX-SM<\/a>, <a href=\"https:\/\/automation.omron.com\/en\/us\/products\/family\/F3SG-SR\">F3SG-SR<\/a>, and <a href=\"https:\/\/automation.omron.com\/en\/us\/products\/family\/D4SL-N\">D4SL-N series<\/a>, visit the links embedded here and above.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For more expert insights from Omron Automation, <a href=\"https:\/\/us.rs-online.com\/expert?s=omron\">check out the company\u2019s other contributions to the RS Expert Advice series<\/a>, including <a href=\"https:\/\/us.rs-online.com\/expert\/overcome-facility-and-intralogistics-challenges-with-industry-4-0\/\">\u201cOvercome facility and intralogistics challenges with Industry 4.0.\u201d<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For assistance identifying, procuring, installing, and maintaining Omron Automation machine safety products and integrated solutions \u2014 or leveraging RS and Omron safety application engineering support \u2014 please contact your local RS representative at <strong>1.866.433.5722<\/strong> or reach out to the <a href=\"https:\/\/us.rs-online.com\/lp\/contact-us\/technical-support\">RS technical support team<\/a>.<\/p>\n<div style='text-align:left' class='yasr-auto-insert-visitor'><\/div>","protected":false},"excerpt":{"rendered":"<p>In this edition of the new Problem? Solved! RS Expert Advice series,Renato Osaki, the Safety Components Product Manager at Omron Automation, explains how smart, turnkey safety relays, light curtains, and guard locking switches solve common machine safety challenges in sprawling conveyor systems and automated cells. RS serves industrial customers who build and maintain assets and [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":7462,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"yasr_overall_rating":0,"yasr_post_is_review":"","yasr_auto_insert_disabled":"","yasr_review_type":"BlogPosting","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[1,1101],"tags":[743,352,1130,764,1129],"class_list":["post-7460","post","type-post","status-publish","format-standard","has-post-thumbnail","category-expert-advice","category-problem-solved","tag-compliance","tag-interlocks","tag-lightcurtains","tag-logistics","tag-safetyrelays"],"yasr_visitor_votes":{"stars_attributes":{"read_only":false,"span_bottom":false},"number_of_votes":0,"sum_votes":0},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/res.cloudinary.com\/mktg-allied-electronics-automation\/image\/upload\/v1784141443\/Expert%20Advice\/Problem__Solved__2000x800_avpdsu.jpg","_links":{"self":[{"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/posts\/7460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/comments?post=7460"}],"version-history":[{"count":22,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/posts\/7460\/revisions"}],"predecessor-version":[{"id":7483,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/posts\/7460\/revisions\/7483"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/media\/7462"}],"wp:attachment":[{"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/media?parent=7460"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/categories?post=7460"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/us.rs-online.com\/expert\/wp-json\/wp\/v2\/tags?post=7460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}